Studio-technologies 591 Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Studio-technologies 591. Studio Technologies 591 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 44
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
50085-999, Issue 1
© 1999 by Studio Technologies, Inc., all rights reserved
5520 West Touhy Avenue
Skokie, Illinois 60077 U.S.A.
Telephone (847) 676-9177
Fax (847) 982-0747
www.studio-tech.com
Model 58 Central Controller and
Model 591 Control Console
User Guide
Issue 1, September 1999
This User Guide is applicable for serial numbers:
Model 58 M58-00351 and later
Model 591 M591-00151 and later
Vedere la pagina 0
1 2 3 4 5 6 ... 43 44

Sommario

Pagina 1 - User Guide

50085-999, Issue 1© 1999 by Studio Technologies, Inc., all rights reserved5520 West Touhy AvenueSkokie, Illinois 60077 U.S.A.Telephone (847) 676-917

Pagina 2 - Table of Contents

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 13The monitor outputs are electronicallybalanced and are capable of driv

Pagina 3 - Foreword

Issue 1, September 1999 Model 58/591 User GuidePage 14 Studio Technologies, Inc.Warning: It is very important thatsignals connected to the bypass inpu

Pagina 4 - Introduction

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 15Remote Control ConnectionsThe remote control input circuitry is physi-

Pagina 5

Issue 1, September 1999 Model 58/591 User GuidePage 16 Studio Technologies, Inc.Connecting the Model 591 tothe Model 58A cable with 9-pin D-sub plugs

Pagina 6

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 17ensure that performance would always becorrect!) Refer to the Configur

Pagina 7 - Applications

Issue 1, September 1999 Model 58/591 User GuidePage 18 Studio Technologies, Inc.in where the trim pots are located in thecircuitry, and why the meter

Pagina 8 - Installation

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 198. If insert 2 is being utilized, repeat theprocedure for its two retu

Pagina 9 - Monitor Outputs

Issue 1, September 1999 Model 58/591 User GuidePage 20 Studio Technologies, Inc.• Reference level• Dim level• Remote contact inputs and level controlT

Pagina 10 - Bypass Inputs

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 21Remote Level ControlTwo configuration choices are associatedwith the r

Pagina 11 - Insert Sends and Returns

Issue 1, September 1999 Model 58/591 User GuidePage 22 Studio Technologies, Inc.monitor output B to become active whenthe bypass mode is active. Also,

Pagina 12 - Remote Control Connections

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 3Table of ContentsForeword ...

Pagina 13 - AC Mains Power

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 23source preset A was selected to be: Input 1routed to the left monitor

Pagina 14 - Configuration

Issue 1, September 1999 Model 58/591 User GuidePage 24 Studio Technologies, Inc.Model 591 Configuration—Entering and ExitingConfiguration ModeThese LE

Pagina 15

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 25Model 591 Configuration—Insert 1 and 2When an insert button is pressed

Pagina 16 - Parameters

Issue 1, September 1999 Model 58/591 User GuidePage 26 Studio Technologies, Inc.Model 591 Configuration—Monitor Output Mode, Power-Up MuteMode, and Re

Pagina 17

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 27Model 591 Configuration—Channels Selected for Bypassand Bypass ModeDef

Pagina 18

Issue 1, September 1999 Model 58/591 User GuidePage 28 Studio Technologies, Inc.Default: Reference level is set for fully attenuated (minimum) monitor

Pagina 19

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 29Model 591 Configuration—Dim Level and Contact InputsPress and hold the

Pagina 20

Issue 1, September 1999 Model 58/591 User GuidePage 30 Studio Technologies, Inc.Press and hold both insert buttons for5 seconds to restore Model 591 f

Pagina 21 - Configuration Mode

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 31OperationNow that you’ve installed and configuredthe system, you’re re

Pagina 22

Issue 1, September 1999 Model 58/591 User GuidePage 32 Studio Technologies, Inc.A/B Output SelectThe A/B button is used to select the moni-tor output

Pagina 23

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 5ForewordSimply stated: I had a blast working on these StudioComm compon

Pagina 24

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 33as a talkback system, to reliably dim themonitor outputs.Rotary Level

Pagina 25 - Input Source Preset

Issue 1, September 1999 Model 58/591 User GuidePage 34 Studio Technologies, Inc.Remote ControlsTwo contact signals and a potentiometercan be connected

Pagina 26

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 35“Hot” Disconnection of the Model 591Control ConsoleShould you need to

Pagina 27

Issue 1, September 1999 Model 58/591 User GuidePage 36 Studio Technologies, Inc.SpecificationsModel 58 Central ControllerGeneral Audio:Frequency Respo

Pagina 28 - Operation

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 37Appendix AControlling the Model 58The Model 58 Central Controller uses

Pagina 29

Issue 1, September 1999 Model 58/591 User GuidePage 38 Studio Technologies, Inc.Function: Reset to Power-Up Default ConfigurationByte Value Descriptio

Pagina 30 - Bypass Function

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 39Function: Input Source and Associated ChannelsByte Value Description1

Pagina 31 - Technical Notes

Issue 1, September 1999 Model 58/591 User GuidePage 40 Studio Technologies, Inc.Function: Monitor Output Channel StatusByte Value Description1 F0H Sys

Pagina 32

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 41Function: Monitor Output Level - NormalByte Value Description1 F0H Sys

Pagina 33 - Specifications

Issue 1, September 1999 Model 58/591 User GuidePage 42 Studio Technologies, Inc.Function: Monitor Output Level - ReverseByte Value Description1 F0H Sy

Pagina 34 - Appendix A

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 7IntroductionWhat This User Guide CoversThis User Guide is designed to a

Pagina 35

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 43Function: Monitor Output A/B StatusByte Value Description1 F0H System-

Pagina 36

Issue 1, September 1999 Model 58/591 User GuidePage 44 Studio Technologies, Inc.Function: Insert 1 StatusByte Value Description1 F0H System-Exclusive

Pagina 37

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 45Function: Insert 2 StatusByte Value Description1 F0H System-Exclusive

Pagina 38

Issue 1, September 1999 Model 58/591 User GuidePage 46 Studio Technologies, Inc.Function: Bypass Status (Supported by Model 58 units with serial numbe

Pagina 39

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 47Function: Input Source to Output 2 (Supported by Model 58 units with s

Pagina 40

Issue 1, September 1999 Model 58/591 User GuidePage 8 Studio Technologies, Inc.parameters. Numerous LEDs providecomplete status information. The Model

Pagina 41

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 9The StudioComm’s two insert sectionsare directly accessible using push-

Pagina 42

Issue 1, September 1999 Model 58/591 User GuidePage 10 Studio Technologies, Inc.level. Contact input 1 can be configuredas either a remote mute all or

Pagina 43

Model 58/591 User Guide Issue 1, September 1999Studio Technologies, Inc. Page 11remote level control input was providedspecifically to allow a produce

Pagina 44

Issue 1, September 1999 Model 58/591 User GuidePage 12 Studio Technologies, Inc.by Studio Technologies. Note that ourfriends in some locations may use

Commenti su questo manuale

Nessun commento